额定补偿电压
|
200...240 V (- 15...10 %)
|
|
|
|
|
|
|
|
|
线路电流
|
6.7 A 时240 V 8 A 时200 V
|
|
|
|
|
|
|
瞬时过转矩
|
150...170 % of nominal motor torque depending on drive rating and type of motor
|
|
|
|
|
|
非对称电机控制配置文件
|
二次电压/频率比 无传感器的通量矢量控制 Voltage/frequency ratio (V/f)
|
|
|
|
|
|
|
|
|
|
|
|
传输率
|
4800 bit/s 9600 bit/s 19200 bit/s 38400 bit/s
|
|
|
|
|
|
|
通信服务
|
读设备标识 (43) 读保持寄存器 (03), messaging: 29 words maximum 写单寄存器(06), messaging: 29 words maximum 写多寄存器 (16), messaging: 27 words maximum 读/写多个寄存器 (23), messaging: 4/4 words maximum
|
|
|
|
|
|
|
|
|
|
|
开关频率
|
2...16 kHz 可调 4...16 kHz 带降额因素
|
|
|
|
|
|
制动力矩
|
Up to 150 % of nominal motor torque with braking resistor at high inertia Up to 70 % of nominal motor torque without braking resistor
|
|
|
|
|
|
|
电气连接
|
L1, L2, L3, U, V, W, PA, PC 端子 3.5 mm² (AWG 12)
|
|
|
|
|
|
|
|
电源
|
Internal supply for reference potentiometer 5 V DC, voltage limits 4.75...5.25 V, 10 mA for overload and short-circuit protection Internal supply for logic inputs 24 V DC, voltage limits 20.4...28.8 V, 100 mA for overload and short-circuit protection
|
|
|
|
|
|
|
模拟量输入类型
|
AI1 可配置电流 0...20 mA, 阻抗 250 欧姆 AI1 可配置的电压 0...10 V, 阻抗 30 kOhm AI1 可配置的电压 0...5 V, 阻抗 30 kOhm
|
|
|
|
|
|
|
离散量输入类型
|
(LI1...LI4) 可编程, 24 V, 电压限制 18...30 V
|
|
|
|
|
|
离散量输入逻辑
|
正逻辑(源), 0...< 5 V (状态 0), > 11 V (状态 1) 负逻辑 (阱), > 16 V (状态 0), < 10 V (状态 1), input impedance 3.5 kOhm
|
|
|
|
|
|
采样期间
|
< 10 ms用于模拟量输入 < 20 ms, 容限 +/- 1 ms用于逻辑输入
|
|
|
|
|
|
线性度误差
|
+/- 0.3 % of maximum value用于模拟量输入
|
|
|
|
|
|
|
模拟输出 型号
|
(AO1) 软件-可配置电压, analogue output range 0...10 V, output impedance 470 欧姆, analogue output resolution 8 位 (AO1) 软件-可配置电流, analogue output range 0...20 mA, output impedance 800 欧姆, analogue output resolution 8 位
|
|
|
|
|
|
|
输出型式
|
(LO+, LO-) 逻辑输出 (R1A, R1B, R1C) protected relay output 1 C/O
|
|
|
|
|
|
***小开关电流
|
5 mA 时24 V 直流用于逻辑继电器
|
|
|
|
|
|
***大开关电流
|
2 A 时250 V AC 电感式 负载 cos phi = 0.4 L/R = 7 ms用于逻辑继电器 2 A 时30 V 直流 电感式 负载 cos phi = 0.4 L/R = 7 ms用于逻辑继电器 3 A 时250 V AC 电阻性 负载 cos phi = 1 L/R = 0 ms用于逻辑继电器 4 A 时30 V 直流 电阻性 负载 cos phi = 1 L/R = 0 ms用于逻辑继电器
|
|
|
|
|
|
加速和减速倾斜
|
从 0 至 999.9 s 线性 S U
|
|
|
|
|
|
|
保护类型
|
线路电源过压 总线供电欠压 输出相线和接地之间的过流 过热保护 电机各相线之间短路 Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t
|
|
|
|
|
|
频率分辨率
|
模拟量输入 A/D 转换器, 10 位 显示单元 0.1 Hz
|
|
|
|
|
|
时间常量
|
20 ms, 容限 +/- 1 ms 用于型号更改
|
|
|
|
|
|
|
|
|
|
|
|
电磁兼容性
|
快速电瞬流/突变抑制测试 (级别 4) 符合 EN/IEC 61000-4-4 静电放电抑制测试 (级别 3) 符合 EN/IEC 61000-4-2 免于传导干扰 (级别 3) 符合 EN/IEC 61000-4-6 传播射频电磁场抑制性测试 (级别 3) 符合 EN/IEC 61000-4-3 电压下降与断路抑制测试 符合 EN/IEC 61000-4-11 浪涌抑制测试 (级别 3) 符合 EN/IEC 61000-4-5
|
|
|
|
|
|
电磁辐射
|
Radiated emissions, class: environment 1 category C2 符合 EN/IEC 61800-3 - test level: 2...16 kHz shielded motor cable Conducted emissions with integrated EMC filter, class: environment 1 category C1 符合 EN/IEC 61800-3 - test level: 2, 4, 8, 12 and 16 kHz, <= 5 m shielded motor cable Conducted emissions with integrated EMC filter, class: environment 1 category C2 符合 EN/IEC 61800-3 - test level: 2...12 kHz, <= 5 m shielded motor cable Conducted emissions with integrated EMC filter, class: environment 1 category C2 符合 EN/IEC 61800-3 - test level: 2, 4 and 16 kHz, <= 10 m shielded motor cable Conducted emissions with additional EMC filter, class: environment 1 category C1 符合 EN/IEC 61800-3 - test level: 4...12 kHz, <= 20 m shielded motor cable Conducted emissions with additional EMC filter, class: environment 1 category C2 符合 EN/IEC 61800-3 - test level: 4...12 kHz, <= 50 m shielded motor cable Conducted emissions with additional EMC filter, class: environment 2 category C3 符合 EN/IEC 61800-3 - test level: 4...12 kHz, <= 50 m shielded motor cable
|
|
|
|
|
|
|
抗振动
|
1 gn (f = 13...200 Hz) 符合 EN/IEC 60068-2-6 波峰至波峰 1.5 mm (f = 3...13 Hz) 驱动器未装在DIN对称导轨上 符合 EN/IEC 60068-2-6
|
|
|
|
|
|
抗冲击
|
15 gn用于11 ms 符合 EN/IEC 60068-2-27
|
|
|
|
|
|
相对湿度
|
5...95 % 无冷凝 符合 IEC 60068-2-3 5...95 % 无滴水 符合 IEC 60068-2-3
|
|
|
|
|
|
|
工作环境温度
|
-10...40 °C 有 取下变频器顶部的保护盖 40...60 °C 电流降额 2.2 %/ °C
|
|
|
|
|
|
海拔高度
|
<= 1000 m 无降容 > 1000...2000 m 电流降额 1%/100m
|
|
|
|